Siemens 6RA70 alarm F004 code reason and troubleshooting method

Siemens 6RA70 alarm F004 code reason and troubleshooting method, 6RA70 alarm code fault consultation, Siemens 6RA70 alarm F004 code, 6RA70 display F004, F004 can not be reset, F004 fault inquiry, F004 what causes the user to use during the process, often meet 6RA70 DC Governor alarm F004 power supply failure, cannot be reset.

Fault reason: F004 alarm activation condition is that the three-phase incoming line voltage is about 20% lower. The three-phase voltage detection is sent to the comparator comparator to the CPU processor to determine the signal level by the voltage divider resistor and activate the alarm code. The thyristor quick-capacity protector burned by the DC governor is burnt. The F004 code will be displayed when the power is turned on. The F004 code cannot be reset. The power sampling signal is open and the power supply will also alarm F004. Damage to the CUD1 control board also activates the alarm.

Troubleshooting method:

1. Observe the display value of R015 and input 380V to the governor. Normally it is 380~400V.

2. Replace the pulse-triggered power board. 3. Replace the CUD1 control board. Siemens DC governor failure analysis. 1. Phase voltage fault in the armature power supply. Symptom: The device cannot be started. Fault No. F004

Possible causes of failure: (1) armature voltage failure; (2) disconnection of the contactor during operation; (3)

The fuse on the AC side of the armature circuit is blown; (4) The fuse of the power component is blown.

2. Excitation circuit fault phenomenon: The device can not start, fault number F005

Possible causes of failure: (1) Excitation phase voltage failure; (2) Disconnected contactor during operation; (3)

The fuse of the excitation circuit is blown.

3, driving stall failure phenomenon: device start, but the hoist did not turn, fault number F035

Possible cause of failure: Heavy load or motor stall.

4. No armature current flowing through the fault Phenomenon: Although the device has been started, no armature current flows through. Fault No. F036

Possible cause of failure: The armature circuit is open circuit.

5, I2t motor monitoring response failure phenomenon: motor overheating, fault number F037

Possible causes of failure: Heavy load for a long time at low speed or overloaded.

6, overweight fault phenomenon: the system in the high-speed time this failure, or just start or run in the reporting fault, fault number F038

Possible causes of failure: (1) Excessive force, high-speed operation, resulting in insufficient braking torque and overspeed;

(2) The shaft encoder is broken or disconnected.

Advantage:
1. Energy-saving
It can be used together with temperature controller to form infrared radiant heating system. According to the temperature needs of the user, the temperature in each room can be freely adjusted. When the indoor temperature reaches the preset temperature, the heating system will automatically stop and the heat accumulator begins to emit heat so as to maintain the preset temperature for a long time, saving energy and power. 
2. Environmenal protection
Its energy is electricity so that is very evironmental.
3. Safety and comfortable
It won't explode or emit odor, wind or noist.
4. Long life expectancy
It can be used more than 20 years.
5. Health care
The heat radiant can change body microcirculation, cell organization under skin producing resonance, clearing the barrier of microcirculation, adjusting and balancing nervous system promoting metabolism, increasing body physical power. It is very good for your health.


Ceiling Mounted Infrared Heater

Ceiling Mounted Infrared Heater,Ceiling Panel Heater,Ceiling Mounted Electric Heater,Ceiling Mounted Room Heater

Shandong Dexiang Electrical Technology Co.,Ltd , http://www.infraredroomheater.com